To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Enterprise SCADA Server

Showing 115 of 774

Add ability for Omnicomm to support secure connections to devices

Enterprise SCADA desires to be at the forefront of security. Many protocols are beginning to support SSL/TLS connections to the end device, thus finally protecting that last few feet of communications from the networking equipment to the device. F...
Collin Heggerud almost 2 years ago in Enterprise SCADA Server / API / SDK / Developer Relations / Omnicomm / Protocols and Commlines / Security and DMZ 7 Reviewing

Add API for protocols to update freshness of point independently from field value

Big Picture User Experience Omnicomm API to allow protocols to update DQ and value with 4 permutations. Bad Quality only, Bad quality With value, Good Quality only and Good Quality with Value. Detailed Description With adoption of more sophisticat...
Collin Heggerud almost 2 years ago in Enterprise SCADA Server 1 Waiting for information

Ability to send historical field data to Historical for previous hour

The original enhancement request is in the attached document.
Guest almost 2 years ago in Enterprise SCADA Server 2 Reviewing

Enhance water-sqrt rate subtype

TS analysis: TS has confirmed that water-sqrt has been an available choice for the rate subtype in 2018 through 2023.(water-sqrt.PNG attached) However, the documentation for rate subtype only lists and describes the other 3 options - linear, liqui...
Natalie Hunter almost 2 years ago in Enterprise SCADA Server 3 Reviewing

CRM Point to Point Verification Enhancement

To address PHMSA finding and to improve commissioning experience, we are looking to add the following data fields to CRM database and improve the existing display to support the fields. Field (with examples) Description Engg Units (Pull from datab...
Guest almost 2 years ago in Enterprise SCADA Server / Applications 0

Request for a new telemetered point type/table

SE PA WWW integrator has industry specific telemetered point type of Water Reservoir. Reservoirs are a type of telemetered point similar to an analog but with additional calculations for volume etc. Prior to binary release integrator modified the ...
Guest almost 4 years ago in Enterprise SCADA Server / Realtime API/SDK / Realtime Schema / Telemetry 1

Increase FlowTotalConfig totalblocks from 4 to 6

Increase the total blocks from 4 to 6 (1 additional as a spare)to enable additional elements to be calculated within one flowTotalConfig Flow Rate [0]Current Hour Accum [1]Previous Hour Accum [2]Current Day Accum [3]Current Month Accum [4]
Vitali Unke 12 months ago in Enterprise SCADA Server 0 Future consideration

Higher Visibility for Datapump Issues

Request that there be a better way to tell when Datapump is not pumping.
John Bjartveit 12 months ago in Enterprise SCADA Server / Datapump 0

Analog field rawval should be replicated to non-owning sites

Client has observed that the ANALOG "rawval" field is not replicating to non-owning sites; and they expect this value to be replicated. Anything else relevant to this feature? There is an optional feature called the "Raw Data Enhancement" RAW_ENAB...
Guest about 2 years ago in Enterprise SCADA Server / Replication 2 Waiting for information

How to install applications from MS store in OT zone