To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 642 of 642

Trend history file modification

Currently any change to a trend in Citect means having to discard the trend history files, for example changing the Sample Period. Would it be possible to have Citect modify the history files automatically? There are tools in the Toolbox to achiev...
Guest about 5 years ago in Plant SCADA / Alarms 1 Future Consideration

Display quality as string intead of Hex in OCMC (SMC)

Hex value indicating the quality of the items in OI Server Device Groups (Diagnostics) is not easily readable. I suggest to replace the Hex values by their String value, or display Hex value and string value like in Object Viewer (eg: C0:Good)
Florian Champalle 7 months ago in Application Server & OMI / OCMC (Previously SMC) 0

Add Param to IoTView Driver INI Files to Disable UDrvCompareAddress Sorting

On the SCADAPack, with 1500 points, it can take 2 minutes for the UDRVCompareAddress sort during IotView startup. This takes a long time for our users and I reached out to Larry asking if it was possible for us to disable the sorty. He says its no...
Guest about 1 month ago in Edge / Tags 0 Needs review

Faster compiler

The old compiler needs to utilize modern hardware better to decrease compile-time. Also applies to other tools who I suspect uses same/similar routines working with DBFs and such. Like page update and packing, etc.
Guest almost 2 years ago in Plant SCADA / Development Tools 0 Future Consideration

Secured and Verify Writes popup for boolean shoud show Onmsg/Offmsg instead of True/False

The popup for secured/verify writes is showing the value True or False. Would be more logical that it uses the OnMsg or OffMsg that is configured for the corresponding attribute.
Lauran Lint 4 months ago in Application Server & OMI / Security 0

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest over 4 years ago in Device Integration 1 Will not implement

Support OMI web client as a PWA

Allow OMI web client to be installed as a Progressive Web Application (PWA)
Ernst Van Wyk 9 months ago in Application Server & OMI / OMI web runtime 0 Planned

MQTT

More and more devices support MQTT protocol
Guest about 5 years ago in Device Integration 5

Process Analyst connects to WW Historian

Process Analyst can connect to Citect Historian ,ref to picture. Then is should be possible to connect to Aveva Historian alias WW Historian.
Guest over 4 years ago in Plant SCADA / Alarms 0 In Roadmap

Call Excel Addin functions from vba

Whe have our own Excel macro's for generating tags, alarm, trends, etc and would like to use the 64bit version of Excel. We want to open a DBF using the Excel Addin, run our own macro and then save the DBF file using vba.
Guest about 1 year ago in Plant SCADA / Development Tools 1 Future Consideration