Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Add rectangle and text properties to buttons and change button and keypad styles

To create a toggle button with color and text animation from a variable, you need to use three things: "button", "text" and "rectangle". It would be useful to transfer the properties to the button from the other two. Then we create one button and ...
Guest 28 days ago in Plant SCADA / Graphics / Visualization 0 Submitted

Update versions active x controls - Process Analyst , Database Exchange or add new ones.

Libraries of Active X haven't been updated in a long time, could use refreshing controls with the new times ;)Everything looks like from 20 years ago.Clients wants New Bargraphs, Gauges, Datapickers for Reports, Textbox, Tables, etc. Are there any...
Guest 9 months ago in Plant SCADA / Graphics / Visualization 3 In Development

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon over 4 years ago in Plant SCADA / Graphics / Visualization 1 Reviewed & Categorized

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 6 years ago in Device Integration 1

New System Tag to receive external commands to Reset the connection on specific devices

Adding an external PLC channel reset System Tag feature would significantly improve operational reliability. This capability is particularly important in scenarios such as PLC reboots, communication interruptions, or network-related outages, where...
Marcel Lima 9 months ago in Device Integration 0

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 2 years ago in Device Integration 4 Planned

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román about 1 year ago in Device Integration 0

Graphics Builder - drawing graphics on layers

This makes drawing large synoptics much easier, because by turning off a given layer you can hide elements. Each object or graphic could have a layer number parameter in its properties. Currently, to apply this, we do it by embedding a genies into...
Guest 9 months ago in Plant SCADA / Graphics / Visualization 0 Unlikely to implement

MQTT

More and more devices support MQTT protocol
Ales B over 6 years ago in Device Integration 5

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest about 6 years ago in Device Integration 1 Will not implement