To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 26 of 776

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 5 years ago in Device Integration 1

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 1 year ago in Device Integration 4

Native MQTT Client

I think it is usefull to add a native MQTT client to Plant SCADA.
Guest over 3 years ago in Plant SCADA / API & Connectivity 4 In Roadmap

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest about 5 years ago in Device Integration 1 Will not implement

MQTT

More and more devices support MQTT protocol
Ales B over 5 years ago in Device Integration 5

Possibility to modify values directly in the SIM OI-Server

For testeing purposes, the OI-Server SIM can be handy. The only missing thing here is the possibility to modify values directly through the UI of it. I now use the WWClient to do this to get the values I want in my Galaxy environment. A added valu...
Lauran Lint 10 months ago in Device Integration 0

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest over 5 years ago in Device Integration 2

Make a connection to a PLC without starting Citect

Often connecting to a PLC can be painful. Any change needs to be compiled, Citect restarted, and then you can test the connection. It would be very handy to have a tool in the Citect Studio that lets you play with parameters, IP addresses, a varia...
Guest over 5 years ago in Plant SCADA / API & Connectivity / Development Tools 1 Future Consideration

Access Anywhere two-factor authentication

Access Anywhere is not compatible with third part apps with two-factor authentication. (I.E. Radious) Ericom support confirmed Access Now does not support Radius. RADIOUS needs a two-factor authentication option, so it is not compatible with Acces...
Eduardo Samper over 3 years ago in Plant SCADA / API & Connectivity 2 Future Consideration

IMS 2459104 KNX ETS 5.100 fan stage support

A customer requested support for KNX ETS 5.100 fan stage support
Peter Chung 7 months ago in Device Integration 0