To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 41 of 776

Native Hardware and Process Historical Alarm logging in SQL database

As current scenario, we can't log historical alarm into SQL database natively. Using alarm category we can log but is has it own limitation. Native functionality like Alarm Upload of CitectHistorian can be real upgrade for CitectSCADA as industry ...
Guest over 5 years ago in Plant SCADA / Alarms 1 Future Consideration

Event Type Trends shows last good value during communication failure

*Form last 3 to 4 years we have been selling and proposing Citect Scada with DNPr driver in Pharmaceutical Companies as a 21CFR compiled Solution. We are using the back-filling feature of DNPr driver with Citect Scada. To use this feature we confi...
Guest over 5 years ago in Plant SCADA / Alarms 0 Future Consideration

to be able to choose constraints in transient mode other than elapsed time

Currently, transient models are constrained to elapsed time. We frequently apply transient models to Steam Turbine run down to compare vibration signatures. A change in vibration during run down could indicate a 'rub' inside the machine or impendi...
Jason Tan over 2 years ago in Predictive Analytics / Model Builder Client 0 Evaluating

3D visual comparison

very often the 2d visual comparison can't show clear correlations between two parameters because of the influence of a 3rd parameter, a 3D visual comparison would show user clearly how signals are inter-correlated with a higher dimension. a exampl...
Jason Tan over 2 years ago in Predictive Analytics / Model Builder Client 2 Tell us more

multi constraint function

to be able to constraint multiple project points in one model. it is useful for equipment with multiple control setpoints such as a distillation column or furnace. in these two cases operator has the freedom to independently adjust multiple contro...
Jason Tan over 2 years ago in Predictive Analytics / Model Builder Client 0 Evaluating

Overlay trends in Web

The idea is to be able to overlay multiple signals on the same trend in Web. The user should be able to select which trends they want to include in the overlay. It should be possible to overlay multiple tags from the same asset (ex. all exhaust te...
Alexander Jenkins over 2 years ago in Predictive Analytics / Web Monitoring Client 0 Planned

Add SwX Alarm page customisation features to SA_Include alarm page

SwX Alarm pages had some useful features that are not available in the Situational Awareness project, for example: Add/Remove columns at runtime Re-order columns at runtime Auto-fit columns It would be great to see these features in the standard S...
Guest about 4 years ago in Plant SCADA / Alarms / Graphics / Visualization 0

Right click on a alarm - Navigate

I have a customer who wishes that users with insufficient privileges are not allowed to "Navigate" to the alarm. So basically. The same behavior as acknowledging and shelving that is greyed out (See the attached picture). Or at least have an optio...
Peter Chung over 1 year ago in Plant SCADA / Alarms 0

PA Web Fault Tree Visualization Customization

Current Fault Tree Visualization structure is showing Project > Fault condition > Fault Diagnostics > Fault Signature. It would be good if further setup UDP with multiple layer hierarchy, for example: Bearing Fault as parent UDP with two ...
Naveen Bandu over 2 years ago in Predictive Analytics / Web Monitoring Client 0 Future consideration

New alarm type (like Double point status alarm) which support 64 states

V2023R2 introduced the double point status alarm. This type of alarm can handle 8 different states. This very limited. Should be at least 32 states or preferrably 64.
Guest almost 2 years ago in Plant SCADA / Alarms 1 Unlikely to implement