Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 123 of 776

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 2 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0

Allow chained VDB field put overrides so integrators can override baseline fields

During development of some CIP functionality for [a customer], (EXT-417), we needed to trigger some protocol specific functionality when the "poll group" field changes. However, when we added a VDB override, it wasn't called. [R&D Architect] h...
Collin Heggerud over 1 year ago in Enterprise SCADA Server / Realtime API/SDK 1 Reviewing

Point to Point Verfication to support multiple systems

Point to Ppoint Verification application should be to work in an enviroment where mulpltle systems are owning datasets.
Vitali Unke 3 months ago in Enterprise SCADA Server 0

Color animation through element properties

You can change an element x, y, width... by accessing its properties through script. Could be helpful to get access to other properties for FillColor, LineColor, ElementStyle,... Attribute could be set by hexacolor. The interest would be to extend...
Mathieu VANTARD about 1 year ago in Application Server / Industrial Graphics 0

DNA Viewer to be allowed to Create/Modify global Trends

No description provided
Vitali Unke 7 months ago in Enterprise SCADA Server 0

Abnormal state enumeration in ADE

Big Picture User Experience This enhancement will improve the point-to-point verification process by aligning the state-enumeration numbering with the states defined in the messageSet table. This will ensure that the field technician and the SCADA...
Vitali Unke 7 months ago in Enterprise SCADA Server 0 Reviewing

(PMFR-479) Alarm Summary display should have a safer mechanism to acknowledge alarms to assure the correct alarm is being acknowledged

Alarm Summary display should have a safer mechanism to acknowledge alarms to assure the correct alarm is being acknowledged PMFR-479
Jake Hawkes over 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

Document all Configuration JSON files

Global Practice has requested that documentation to catalog the various user-modifiable JSON files and their full list of parameters, potential values, limitations, and most importantly their purpose and effect on the system. They have also asked ...
Jason New over 2 years ago in Enterprise SCADA Server / Administration / Installation / Documentation 1 Future consideration

Modern text input animation

Please update the text input animation by disabling the text input popup that appears on element when enabling userinput animation. This instaneoulsy destroy any U.I. / U.X. effort. Could be nice to include custom Regex rules -> avoid scripting...
Mathieu VANTARD about 1 year ago in Application Server / Industrial Graphics 1

Point Conditioning application should support point conditioning updates from multi threaded callers

[customer] experienced lock contention issues when updating point conditioning inputs from within ACE code. Investigation into this issue in support case https://gcsservicecloudutils.azurewebsites.net/casedetails?casenumber=960273706 and R&D I...
Andrew Potkins 10 months ago in Enterprise SCADA Server / Realtime 0