To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Enterprise SCADA Server

Showing 98

Increase FlowTotalConfig totalblocks from 4 to 6

Increase the total blocks from 4 to 6 (1 additional as a spare)to enable additional elements to be calculated within one flowTotalConfig Flow Rate [0]Current Hour Accum [1]Previous Hour Accum [2]Current Day Accum [3]Current Month Accum [4]
Vitali Unke 7 months ago in Enterprise SCADA Server 0 Future consideration

Higher Visibility for Datapump Issues

Request that there be a better way to tell when Datapump is not pumping.
John Bjartveit 7 months ago in Enterprise SCADA Server / Datapump 0

Alarm suppression with an analog parent-value comparator.

Alarm suppression with an analog parent-value comparator. Idea collected at Pipeline Summit 2023
Guest over 1 year ago in Enterprise SCADA Server / Alarms 0

Add API for protocols to update freshness of point independently from field value

Big Picture User Experience Omnicomm API to allow protocols to update DQ and value with 4 permutations. Bad Quality only, Bad quality With value, Good Quality only and Good Quality with Value. Detailed Description With adoption of more sophisticat...
Collin Heggerud over 1 year ago in Enterprise SCADA Server 1 Waiting for information

Enhance water-sqrt rate subtype

TS analysis: TS has confirmed that water-sqrt has been an available choice for the rate subtype in 2018 through 2023.(water-sqrt.PNG attached) However, the documentation for rate subtype only lists and describes the other 3 options - linear, liqui...
Natalie Hunter over 1 year ago in Enterprise SCADA Server 2 Reviewing

flowTotalConfig integration blocks replication enhancement request

Our customer has a business need to be able to manually adjust previous hour/day/month etc of a flowTotal record. So that it provides accurate information in the control room so that GCN records can be met and gas used can be properly tracked.Ofte...
Vitali Unke 9 months ago in Enterprise SCADA Server 0

Dnaswana with DALPrompter

Dnaswana needs the ability to be run on a system that has no RealTime server. For example, GRT project uses support computers on RDS systems (with no Realtime services on there) and needs to run dnaswana from those computers and get traffic data f...
Vitali Unke over 1 year ago in Enterprise SCADA Server / Architecture / Omnicomm / Security and DMZ 0

Analog field rawval should be replicated to non-owning sites

Client has observed that the ANALOG "rawval" field is not replicating to non-owning sites; and they expect this value to be replicated. Anything else relevant to this feature? There is an optional feature called the "Raw Data Enhancement" RAW_ENAB...
Guest over 1 year ago in Enterprise SCADA Server / Replication 2 Waiting for information

How to install applications from MS store in OT zone

Some support applications are only available in the MS Store, but the LTSC versions of the OS do not come with the MS store installed, nor do we want to install it.

MoC Extensions Disabled by Default

As a system integrator I would prefer to see MoC extensions disabled by default, to be enabled if needed, in order to remove this from the required lists of tasks to be executed for a system installation having MoC.
Tyson Burr 10 months ago in Enterprise SCADA Server 0