Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 470 of 470

Unify automatic generation of Configuration Parameters in Plant SCADA Studio 2023 and Equipment Editor

Currently when adding new Equipment through Equipment Editor, all relevant Configuration Parameters will be generated automatically and are available in Plant SCADA Studio 2023. However if you add a new Equipment in Plant SCADA Studio and run "Upd...
Guest about 1 year ago in Plant SCADA / Equipment 1

Add ability to lock guidelines in Graphics Builder (so they dont change when you accidentally click them)

The problem is: in the graphics builder the guidelines can be clicked or dragged using the mouse, and then they change! Whilst dragging is quite a conscious action, clicking something is easily done accidentally. You are not warned that you clicke...
Guest over 2 years ago in Plant SCADA / Graphics / Visualization 1 Unlikely to implement

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest about 4 years ago in Device Integration 2

Improvements of the deployment functionality

Deploying a project can be slow, especially upoading a new version of the project. A progression bar with remaining time would be nice. Would be a nice feature if you could upload the complete project including the configuration files. Have an opt...
Guest over 1 year ago in Plant SCADA / Development Tools 3

Add 'Go To Definition' in Cicode Editor

Allow the user to right click on a User Defined Cicode Function within a code segment and select 'Go To Definition' to navigate to the selected function definition. Optionally provide the ability to select 'Back' to navigate to last cursor positio...
Guest about 4 years ago in Plant SCADA / Development Tools 0 Future Consideration

Native Hardware and Process Historical Alarm logging in SQL database

As current scenario, we can't log historical alarm into SQL database natively. Using alarm category we can log but is has it own limitation. Native functionality like Alarm Upload of CitectHistorian can be real upgrade for CitectSCADA as industry ...
Guest about 4 years ago in Plant SCADA / Alarms 1 Future Consideration

S7TCP-driver to support firmware 3

New Siemens S7-1500 controllers have firmware 3. The S7TCP doesn’t support this firmware version
Guest 6 months ago in Device Integration 0

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest 7 months ago in Plant SCADA / Drivers / Protocols 1

Allow copy from Cicode Editor - Stack window

In debug mode we can select some text from the stack window, but i't impossible to copy and paste it somewhere else. For instance, a sql query string that doesn't work and we would like to copy it to the sql to check what is the mistake.
Guest about 4 years ago in Plant SCADA / Development Tools 0 Future Consideration

Make a connection to a PLC without starting Citect

Often connecting to a PLC can be painful. Any change needs to be compiled, Citect restarted, and then you can test the connection. It would be very handy to have a tool in the Citect Studio that lets you play with parameters, IP addresses, a varia...
Guest about 4 years ago in Plant SCADA / API & Connectivity / Development Tools 1 Future Consideration