To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 142

Document all Configuration JSON files

Global Practice has requested that documentation to catalog the various user-modifiable JSON files and their full list of parameters, potential values, limitations, and most importantly their purpose and effect on the system. They have also asked ...
Jason New over 2 years ago in Enterprise SCADA Server / Administration / Installation / Documentation 1 Future consideration

Undo for redefined values for UDT data type

We can redefine/override values on some level of UDT template structure (MinEU, MaxEU, Alarm Group etc.) But once it is done, there is no way to undo it, and ensure that the UDT type inherits the value again from its ancestor data type (as if it w...
Pavel Prusa 5 months ago in InTouch HMI 0 Planned

When multiple language settings are configured, you can designate a specific language as the default language, and launch the application in development with the default language while displaying the non-default languages.

At present, it can be seen that InTouchView only uses the language selected during installation as the starting language when it starts up. In multi-language usage scenarios, a target language has to be selected each time, which is an unnecessary ...
Penghui Bi 5 months ago in InTouch HMI 1

Stop modifying Industrial Graphics when opening WindowMaker

Every time WindowMaker is opened, all Industrial Graphics get touched with a new date/time. This results in NAD or manual sync operations sending all the graphics each time despite nothing actually having changed.
Andrew Flournoy over 1 year ago in InTouch HMI 0

Point Conditioning application should support point conditioning updates from multi threaded callers

[customer] experienced lock contention issues when updating point conditioning inputs from within ACE code. Investigation into this issue in support case https://gcsservicecloudutils.azurewebsites.net/casedetails?casenumber=960273706 and R&D I...
Andrew Potkins 11 months ago in Enterprise SCADA Server / Realtime 0

Make Alarm Hotbackup Manager fully integrated into InTouch

The utility named Alarm Hotbackup Manager isn't a service nor needs to stay running. It simply makes an INI that is utilitized by InTouch runtime. Then alarms are sycned via an inocuous alarm grid with a query calling for said named pair. Why isn'...
Andrew Flournoy over 1 year ago in InTouch HMI 1

NMC Start All Services on Computer

As a SCADA Administrator, I would like to be able to start all services on machines within my environment in addition to existing service-by-service capabilities, so that I can save time during service startup activities such as post-patching.
Tyson Burr over 1 year ago in Enterprise SCADA Server / Administration / Installation / Architecture 0

Make it easier to run Enterprise SCADA (OASyS) in the cloud

Background More and more opportunities are asking for Enterprise SCADA to be run in the cloud in a PaaS environment such as AWS, Azure and other PaaS vendors. Currently, the product is designed solely for on-premise deployments, and there are cert...
Kevin Mackie almost 2 years ago in Enterprise SCADA Server / Cloud 2 Planned

Add heartbeat support for all telemetered tables

The heartbeat functionality should be applicable to any telemetered table not just analog and status.
Mike Demcoe 6 months ago in Enterprise SCADA Server 0

OPC DA to read Json file to update allowlist/whitelist regularly without restart the OPC server

As you know, every time we add a new database point to the allowlist/whitelist in the OPC Json file, we need to restart the OPC server process for the new configuration to take effect. It is disruptive. So, I was wondering if there is any way to h...