Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Enterprise SCADA Server

Showing 98

Request disabling NetBios be validated

This request created created from a Pembins 2018 SP3 inquiry but I believe it has been agreed to only be considered for supported versions or future release. Previous IMS from ConEd - 2178824 was closed stating, "noting they need to validate the c...
Serge LeBlanc almost 2 years ago in Enterprise SCADA Server / Administration / Installation / Architecture / Security and DMZ 1 Planned

Enhance Device Rollup to support subdevices from multiple datasets

Big Picture User Experience Enhance device rollup from subdevices (telemetered and device object) that belong to datasets that differ from the parent device (top-level device) object dataset. Background With large systems it is now very common to ...
Guest almost 2 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0 Planned

GroupArea in the area table only contains the first 20 groups

Do we actually have a limit of 20 groups per area? Some testing has shown that one can add more then 20 groups into an area. The GroupAreaJoin table populates all of them correctly however the "group[0-19].name” array-field in the area table only ...
Bradley Tomanik almost 2 years ago in Enterprise SCADA Server / Administration / Installation / Realtime 1 Already exists

Multi-system support for HMI

User Story As a pipeline operator / supervisor monitoring pipeline assets that span multiple RealTime environments, I would like to be able to connect my HMI to the combined multi-RealTime environment, conferring all benefit of functionality co...
Tyson Burr almost 4 years ago in Enterprise SCADA Server / Architecture / Control Room Management 1 Future consideration

User alarm limits should obey existing alarm deadbanding configuration

After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration for the alarm level deadband configured for the point. For example: A user high alarm configured at 100 will ring into ...
Guest almost 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

Add 'Workstation Administrator' Role to Active Directory

Big Picture User Experience Following the Principle of Least Privilege, AD-Tiering and now Enterprise Access Model , add 'Workstation Administrator' Role to Active Directory to enable a separation of duties between server administrators and deskto...
Julian Reyes Riveros about 2 years ago in Enterprise SCADA Server / Security and DMZ 0 Planned

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest about 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 0 Reviewing

User alarm limits should obey existing alarm deadbanding configuration

Big Picture User Experience User alarm limits should obey existing alarm deadbanding configuration Detailed Description After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration...
Guest about 2 years ago in Enterprise SCADA Server 0 Reviewing

Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts

We (TCE) would like to find out if Aveva would be able to enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts. We have turned bulk load off for now but would like to see if we could get this enhancement so we co...
Rob Kenny about 2 years ago in Enterprise SCADA Server / Datapump 0 Reviewing

Make Email Alarms generic to support 3rd party notification systems

No description provided
Jake Hawkes about 2 years ago in Enterprise SCADA Server 0 Future consideration