To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Enterprise SCADA Server

Showing 116 of 775

User alarm limits should obey existing alarm deadbanding configuration

After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration for the alarm level deadband configured for the point. For example: A user high alarm configured at 100 will ring into ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 0 Reviewing

User alarm limits should obey existing alarm deadbanding configuration

Big Picture User Experience User alarm limits should obey existing alarm deadbanding configuration Detailed Description After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration...
Guest over 2 years ago in Enterprise SCADA Server 0 Reviewing

Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts

We (TCE) would like to find out if Aveva would be able to enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts. We have turned bulk load off for now but would like to see if we could get this enhancement so we co...
Rob Kenny over 2 years ago in Enterprise SCADA Server / Datapump 0 Reviewing

Make Email Alarms generic to support 3rd party notification systems

No description provided
Jake Hawkes over 2 years ago in Enterprise SCADA Server 0 Future consideration

Parent state alarm suppression

No description provided
Jake Hawkes over 2 years ago in Enterprise SCADA Server 0 Reviewing

Y2K38 Preparedness

Big Picture User Experience The Year 2038 problem (also known as Y2038, or Y2K38, or the ‘Epochalypse’) is a time datatype bug involving the use a signed 32-bit integer to store of Unix time. The data type is only capable of representing integers ...

Request for year to be added to the runtime structure

We've previously added an additional "year" field to the runtime structure to track hours per year for a 7.5 project. I'd like to request an enhancement to OASyS 2021 to add "year" to the runtime structure please. I see that there's a runtimeyear....
Natalie Hunter almost 4 years ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime Schema 5 Will not implement

Ability to add new fields to almsum/event tables in ES2021

One of our water projects will be upgrading to 2021 (or 2022) from 7.5. They've previously customized their almsum and event tables to include an additional field (a record name from a custom table). I know that we can add fields to Realtime table...
Natalie Hunter almost 4 years ago in Enterprise SCADA Server / Alarms / Realtime Schema 2 Waiting for information

Capture the desired precision for analogs in the backend for use by the HMI

Big Picture User Experience Customers desire to configure the number of decimal places used when displaying floating point numbers on the alarm summary only. Detailed Description The current workaround is to use the internationalisation feature to...
Jake Hawkes almost 5 years ago in Enterprise SCADA Server / Control Room Management 1 Will not implement