To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 40 of 859

[PlantSCADA] Ability to Historize other Data Type (like INT/REAL)

4.1 Be able to Historize other Data Type (like INT/REAL) of tag variables , not just the Digital/String Data Types Looks like this is done by choice or some other reasons, e.g. name clashes. The Connector code currently explicitly filters out vari...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 0 In Roadmap

AVEVA Historian official support for Proxmox VE

I would like to propose the inclusion of Proxmox Virtual Environment (VE) as a supported hypervisor platform for AVEVA Historian. Proxmox VE is a robust, open-source virtualization solution that combines KVM and LXC with a powerful web interface a...
Jeffrey Tambach 6 months ago in Historian & Client / Install and Upgrade 0 Submitted

Add Area Hierarchy Filter/Query Support for OMI Alarm App in Historical Alarm Mode

In the Current Alarms mode, users can easily view alarms by area using the Area Hierarchy if shown. However, if you show the Hierarchy menu when the Alarm App is in Historical Alarms mode, selecting an area has no effect on the returned alarms. Us...
Laura Morris 7 months ago in Application Server / Alarm App 0

Support Controls on Industrial graphics for OMI web client (Blazor and Angular)

InTouch supports .NET controls on graphcis but OMI does not. With the introduction of the Blazor web client technology, there is an opportunity to address this parity gap. It is proposed that web client allows the placement of controls (specifical...
Ernst Van Wyk over 1 year ago in Application Server / OMI Apps / OMI web runtime 0

Change tab in multiple or tabbed pane by script

This request would greatly enhance the OMI user experience e.g. when heavy graphics are involved. When using OMI with multiple or tabbed panes, it would be very useful to be able to select already loaded content in a multiple or tabbed pane via sc...
Eivind Fotland 5 months ago in Application Server / OMI Apps 0

Allow flashing and color configuration for individual columns in OMI alarm app

Ability to choose whether color and blinking applies to entire row or selected column - at least for priority and severity
Ernst Van Wyk over 1 year ago in Application Server / Alarm App 1 Planned

Shelving of alarms not working within OMI Navigation App

Shelving alarms is a useful function, and works fine within the alarm apps in OMI. But when enabling alarming function in the Navigation menu in OMI, shelving alarms does not affect navigation menu. Leading to the operators stop using shelve funct...
Eivind Fotland over 1 year ago in Application Server / Other OMI apps 0

[PlantSCADA] Better support for tag config changes on PlantSCADA end

4.3 Changes to Plant SCADA configuration Where there are changes from the PlantSCADA side, a restart of the connector is required however there are many cases of where the users forget to do this. A reminder message may help. Looks like this is do...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 0 In Roadmap

[PlantSCADA] Fault tolerance to errors on the PlantSCADA side

2.0 Fault Tolerance of the connector to SCADA misconfiguration If there is a misconfiguration on the SCADA side, for example after the system is running, then it can lead to the ctapi connection being dropped and no logs for all tags, and not just...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 1 In Roadmap

[PlantSCADA] Make connector activity visible in PlantSCADA UI

The main issue is that if you stop Plant SCADA while a backfilling operation is ongoing but the Connector is still working, then we get the issue that data is written on wrong blocks into historian. To successfully complete the backfill operation,...
Mats-Peter Cansund 6 months ago in Historian & Client / Data Acquisition 3 In Roadmap