To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 35 of 776

BACNET: Addressing objects via ObjectName

We have several requests for accessing BACNET objects via their "ObjectName", rather than their HW address ie: AI.1.PresentValue. There are 2 issues with the current way of addressing: Makes it difficult to make equipment Some PLC’s (ie Wago) shif...
Guest over 5 years ago in Device Integration 1

S7TCP support for firmware V3.0 with username and password

To increase security this option is available on the S7-1500 controller. Without a username and password anyone connected to the network can connect, browse and change values.
Guest over 1 year ago in Device Integration 4

Speed Up Equipment Update

Anyone who has to rename/edit equipment in Studio
Guest 26 days ago in Plant SCADA / Equipment 0 Future Consideration

Copy+Paste items inside Equipment editor

If we need to add an equal or similar item to several equipments we need to type everything, or if we have several tags in the same equipment and want to add an alarm to all of them, it should be useful to copy the alarm part from one item to othe...
Guest over 5 years ago in Plant SCADA / Development Tools / Equipment 1 Future Consideration

Unify automatic generation of Configuration Parameters in Plant SCADA Studio 2023 and Equipment Editor

Currently when adding new Equipment through Equipment Editor, all relevant Configuration Parameters will be generated automatically and are available in Plant SCADA Studio 2023. However if you add a new Equipment in Plant SCADA Studio and run "Upd...
Guest almost 3 years ago in Plant SCADA / Equipment 1

BTL listing of Bacnet driver

We are getting a lot of feedback in the market about us not being BTL listed as a compliant B-AWS/ B-OWS. We see this being demanded in more and more tenders, so I was wondering if this is something you have looked at. The basic stuff for B-OWS se...
Guest about 5 years ago in Device Integration 1 Will not implement

MQTT

More and more devices support MQTT protocol
Ales B over 5 years ago in Device Integration 5

Edit Equipment types with a table tool like Excel

when it is needed to update a lot (not all) of variable and trend definitions for example Historian = true within an equipment type. Browsing to the item, opening the definition, add the field and set the value to true will take a lot of time. Whe...
Guest almost 3 years ago in Plant SCADA / Equipment 3 Unlikely to implement

Equipment editor use patterns

When creating Equipment types it will save a lot of time when it is possible to use pattern’sFor example when creating an alarm several Item’s need to be created with the same structure: <alarm>_Suppression <alarm>_Condition <alarm&...
Guest almost 3 years ago in Plant SCADA / Equipment 2 Future Consideration

Possibility to modify values directly in the SIM OI-Server

For testeing purposes, the OI-Server SIM can be handy. The only missing thing here is the possibility to modify values directly through the UI of it. I now use the WWClient to do this to get the values I want in my Galaxy environment. A added valu...