To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 126 of 776

Include the Tank functionality in the baseline portion of the product

The Tank table is tied to the LMS apps and does not get exposed on a baseline system where some customers could benefit from its built in nature. Allowing a customer to use the Tank table (and the new FlexTank object) as opposed to a custom reserv...
Guest 10 days ago in Enterprise SCADA Server / Applications 1

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke 16 days ago in Enterprise SCADA Server / Alarms 0

Implement Quickscripts for OMI and OMI web client

InTouch has a concept of reusable quick scripts. We need that for Application server as well as for OMI and OMI web client. Especially for use in OMI web client, these "quick scripts" should be able to: Execute local (in browser) or remote (on ser...
Ernst Van Wyk over 1 year ago in Application Server / Application Server Runtime / OMI desktop runtime / OMI web runtime 1 Planned

Support for longer object names

Currently object names in System platform can only have up to 32 characters. We need to support longer names (preferably 128) for object names These names should pull through ti Historian and OMI as well.
Ernst Van Wyk over 1 year ago in Application Server / Application Server Runtime / IDE / OMI desktop runtime / OMI web runtime 0 Planned

Remove Engine Option

Kill Platform is a good utility that is available to remove Platform if its stuck in deployment/undeployment however nothing like that exists for engine. But most of the times, the platform i& other engines are working fine. A utility to remov...
Lakshay Mundeja 10 months ago in Application Server / Application Server Runtime 2

Object Performance Index

Helping users understand the resource requirements Most aspects of perfromance is dependent on the object's complexity, but there is no good way to measure that complexity. This is also required to help with the queuing mechanism described above, ...
Ernst Van Wyk about 1 year ago in Application Server / Application Server Runtime / IDE 0 Planned

SPS version 11 support for RTUPlayer and Trainer.

Requesting support for SPS 11.1 and Windows Server 2022 operating system for RTU Player and Trainer applications.
Andrew Potkins 2 months ago in Enterprise SCADA Server / Applications 0

Allow the "safety string" to be moved or disabled in the alarm message

Currently in baseline, (SAFETY) is always added as a prefix to Safety Related alarm messages. It is used as the marker whether the alarm should be recorded in the event table as safety-related. Our customer wants to have (SAFETY) as a suffix for t...
Hugh Arai 2 months ago in Enterprise SCADA Server / Alarms 0

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...
Collin Heggerud 2 months ago in Enterprise SCADA Server / Omnicomm 0

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 2 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0