Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 39 of 776

Enhance Device Rollup to support subdevices from multiple datasets

Big Picture User Experience Enhance device rollup from subdevices (telemetered and device object) that belong to datasets that differ from the parent device (top-level device) object dataset. Background With large systems it is now very common to ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0 Reviewing

User alarm limits should obey existing alarm deadbanding configuration

After configuring user alarms using the “user hi” and “user lo” functionality, alarms are being generated without consideration for the alarm level deadband configured for the point. For example: A user high alarm configured at 100 will ring into ...
Guest over 2 years ago in Enterprise SCADA Server / Alarms 0 Reviewing

Multiple transient state support for multistate command

Detailed Description Due to various physical factors, sometimes a 2-bit status point will transition through both the (valid) TRANSIT state as well as the (invalid) ERROR state, on its way from CLOSED to OPEN (or vice versa). This enhancement will...
Guest over 2 years ago in Enterprise SCADA Server / Alarms / Krunch and Data Manipulation 0 Reviewing

DNP3 - "Listening mode"

The current version of DNPR or DNP3 driver always want's to initiate the start of communication with the device. There are some devices that work in an opposite direction (i.e. Metasphere DNP3 data loggers https://www.metasphere.co.uk/products/poi...
Ales B over 5 years ago in Device Integration 0

Citect OPCUA Client Driver - Configuring Subscription Sampling Interval to something other than double the subscription rate.

As mentioned in OPC UA driver help (OPCUA Driver > Advanced Configuration and Maintenance > Subscription Management) : "The driver sets the OPC UA subscription sampling interval equal to be half of the publishing interval." Means setting the...
Guest over 3 years ago in Device Integration 1

Ability to add new fields to almsum/event tables in ES2021

One of our water projects will be upgrading to 2021 (or 2022) from 7.5. They've previously customized their almsum and event tables to include an additional field (a record name from a custom table). I know that we can add fields to Realtime table...
Natalie Hunter almost 4 years ago in Enterprise SCADA Server / Alarms / Realtime Schema 2 Waiting for information

Ability to filter out parked alarms from alarm summary screen

Big Picture User Experience TransGas would like to have the ability to hide parked alarms from the alarm summary display. They use alarm parking extensively and feel that having the parked alarms shown on the display makes it more difficult for th...
Todd Cherry almost 5 years ago in Enterprise SCADA Server / Alarms / Control Room Management / Realtime API/SDK 1 Will not implement

Alarm Message to record current and previous states of points

Big Picture User Experience Improve SCADA Controller situational awareness by including prior state of the point when new alarm is generated. Detailed Description Currently, when analog point changes state to an abnormal state and results in alarm...
Vitali Unke 6 months ago in Enterprise SCADA Server / Alarms 0 Reviewing

Alarm should be generated when Omnicomm stops polling a connection record due to being added to the bad hosts list

Create an alarm when omnicomm detects DNS issues and puts a connection offscan.
Jake Hawkes about 2 years ago in Enterprise SCADA Server / Alarms / Omnicomm / Protocols and Commlines 1 Reviewing