To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Enterprise SCADA Server

Showing 66

Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts

We (TCE) would like to find out if Aveva would be able to enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts. We have turned bulk load off for now but would like to see if we could get this enhancement so we co...
Rob Kenny over 1 year ago in Enterprise SCADA Server / Datapump 0 Will not implement

Make Email Alarms generic to support 3rd party notification systems

No description provided
Jake Hawkes over 1 year ago in Enterprise SCADA Server 0 Future consideration

Allow customers to latch alarms

Here is one problem customers are encountering with our alarming philosophy, where we replace the existing alarm with a new one with the current alarm state: Because the alarm for exceeding hi-hi isn’t latched, operators are missing that MAOP was ...
Collin Heggerud over 4 years ago in Enterprise SCADA Server / Alarms / Control Room Management 0

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu over 4 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing

Request for year to be added to the runtime structure

We've previously added an additional "year" field to the runtime structure to track hours per year for a 7.5 project. I'd like to request an enhancement to OASyS 2021 to add "year" to the runtime structure please. I see that there's a runtimeyear....
Guest over 2 years ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime Schema 5 Will not implement

Alternate timeseries hourly averaging algorithm

Enhancement request to either allow integrators to modify timeseries averaging algorithm or provide hooks to allow integrator to modify the operation. We implemented an alternative timeseries averaging algorithm on many installations. Prior to bin...
Guest almost 3 years ago in Enterprise SCADA Server / Historical / Realtime API/SDK 1

Ability to add new fields to almsum/event tables in ES2021

One of our water projects will be upgrading to 2021 (or 2022) from 7.5. They've previously customized their almsum and event tables to include an additional field (a record name from a custom table). I know that we can add fields to Realtime table...
Guest almost 3 years ago in Enterprise SCADA Server / Alarms / Realtime Schema 2 Waiting for information

Expansion of point description field string length

SE PA WWW previously modified database schema and structure now with binary release modifications tot he database structure are limited. Support for modifying existing types including changing string length is not supported. SE PA WWW typically...
Guest almost 3 years ago in Enterprise SCADA Server / Realtime Schema 3 Will not implement

Capture the desired precision for analogs in the backend for use by the HMI

Big Picture User Experience Customers desire to configure the number of decimal places used when displaying floating point numbers on the alarm summary only. Detailed Description The current workaround is to use the internationalisation feature to...
Jake Hawkes over 3 years ago in Enterprise SCADA Server / Control Room Management 1 Will not implement

Ability to filter out parked alarms from alarm summary screen

Big Picture User Experience TransGas would like to have the ability to hide parked alarms from the alarm summary display. They use alarm parking extensively and feel that having the parked alarms shown on the display makes it more difficult for th...
Todd Cherry over 3 years ago in Enterprise SCADA Server / Alarms / Control Room Management / Realtime API/SDK 1 Will not implement